106 resultados para Operational indicators

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water-based colourimetric indicator films are shown to have increased operational lifetimes under ambient conditions compared to similar solvent-based counterparts. The response and sensitivity characteristics of a water-based, carbon dioxide-responsive ink are characterised and compared and contrasted to those of a similar solvent-based indicator. The changes in the response characteristics of the ink as a function of the amount of base (sodium hydrogen carbonate) and plasticizer (glycerol) contained in the ink are reported, as are the effects of varying ambient temperature and humidity. The ink is incorporated into a felt tip pen and applied to a number of different substrates, producing a distinct, reversible colour change on all tested surfaces, when a sufficient level of carbon dioxide is present. The possible application of the indicator is discussed briefly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International policy frameworks such as the Common Fisheries Policy and the European Marine Strategy Framework Directive define high-level strategic goals for marine ecosystems. Strategic goals are addressed via general and operational management objectives. To add credibility and legitimacy to the development of objectives, for this study stakeholders explored intermediate level ecological, economic and social management objectives for Northeast Atlantic pelagic ecosystems. Stakeholder workshops were undertaken with participants being free to identify objectives based on their own insights and needs. Overall 26 objectives were proposed, with 58% agreement in proposed objectives between two workshops. Based on published evidence for pressure-state links, examples of operational objectives and suitable indicators for each of the 26 objectives were then selected. It is argued that given the strong species-specific links of pelagic species with the environment and the large geographic scale of their life cycles, which contrast to demersal systems, pelagic indicators are needed at the level of species (or stocks) independent of legislative region. Pelagic community indicators may be set at regional scale in some cases. In the evidence-based approach used in this study, the selection of species or region specific operational objectives and indicators was based on demonstrated pressure-state links. Hence observed changes in indicators can reliably inform on appropriate management measures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the contribution of accumulated winter precipitation and glacial meltwater to the recharge of deep ground water flow systems in fracture crystalline rocks, measurements of environmental isotope ratios, hydrochemical composition, and in situ parameters of ground water were performed in a deep tunnel. The measurements demonstrate the significance of these ground water recharge components for deep ground water flow systems in fractured granites of a high alpine catchment in the Central Alps, Switzerland. Hydrochemical and in situ parameters, as well as d18O in ground water samples collected in the tunnel, show only small temporal variations. The precipitation record of d18O shows seasonal variations of ~14‰ and a decrease of 0.23‰ ± 0.03‰ per 100 m elevation gain. d2H and d18O in precipitation are well correlated and plot close to the meteoric water line, as well as d2H and d18O in ground water samples, reflecting the meteoric origin of the latter. The depletion of 18O in ground water compared to 18O content in precipitation during the ground water recharge period indicates significant contributions from accumulated depleted winter precipitation to ground water recharge. The hydrochemical composition of the encountered ground water, Na-Ca-HCO3-SO4(-F), reflects an evolution of the ground water along the flowpath through the granite body. Observed tritium concentrations in ground water range from 2.6 to 16.6 TU, with the lowest values associated with a local negative temperature anomaly and anomalous depleted 18O in ground water. This demonstrates the effect of local ground water recharge from meltwater of submodern glacial ice. Such localized recharge from glaciated areas occurs along preferential flowpaths within the granite body that are mainly controlled by observed hydraulic active shear fractures and cataclastic faults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the difficult problem of how to improve the process of evaluating organisational change. Given that the data emergent from an evaluative exercise will strongly influence the subsequent strategic and operational decisions taken by organisational managers, it is critical that the evaluation approach itself is capable of delivering high quality, accurate and timely data. The aim of this paper is to examine the role of the IT-based Optionfinder Technology used in conjunction with focus groups, in generating management decision-making data, and reflecting the changes in key performance indicators in a utility organisation. The case study research evaluates the innovative integrative approach adopted by the utility organisation and concludes that the proposed approach contributes to improvements in the decision-making capability of managers.